Guide · 8 min read

Tank sensors, explained properly

Six technologies measure liquid in a tank. Five of them have a catch. Here’s how each works, where each fails, and a straight way to choose.

The two families: inside or outside

Every tank sensor belongs to one of two families. Contact sensors live inside the tank or in a fitting through its wall: floats, capacitive probes, and pressure sensors.

Non-contact sensors measure from outside the liquid — or outside the tank entirely: ultrasonic, radar, vibration.

The family matters more than the technology. Anything inside a tank shares its fate: waste coats it, fuel varnishes it, scale grows on it, and the hole it came through ages. Outside the tank, none of that exists. Keep that in mind as we go through the list.

1. Float senders — the petrol-classic

A swing arm or vertical float rides the surface and moves a resistor. Cheap, universally understood, and the reason your fuel gauge moves. The catches: moving parts in dirty liquid (the classic stuck float), coarse resolution in 10–25 % steps, a hole in the tank, and readings that dance in a seaway. Fine for a car. Frustrating in a boat and on an RV and in a mobile home.

2. Capacitive probes & strips

The liquid changes the capacitance around a probe (inside) or a strip (glued to the outside of a plastic wall). No moving parts, which is progress. But probes coat over in waste tanks and read wrong as the coating grows; strips need a clean vertical run on a non-conductive wall and recalibrate poorly for odd shapes. Metal tanks short the principle out entirely.

3. Pressure senders

Liquid weight is pressure: measure at the bottom, get the height. Accurate and shape-independent in tall, calm tanks — genuinely good in industry. In small mobile tanks the signal is tiny (a 60 cm water column is just 0.06 bar), sloshing destroys it, and the sensor sits in the liquid through a bottom fitting — the single worst hole to ever have leak.

4. Ultrasonic — sonar in a box

A transducer pings the surface and times the echo. Works in open silos. In a small closed tank it fights condensation on its own face, foam and vapour absorbing the echo, a 20–30 cm dead zone right where small-tank surfaces live, and the speed of sound drifting with every degree of temperature. It also can’t see through any tank wall, so external mounting is out. Full radar vs ultrasonic comparison →

5. Radar — the modern answer for plastic tanks

Same echo idea, but with electromagnetic waves at GHz frequencies: indifferent to condensation, vapour, foam and temperature, accurate to millimetres at close range. The party trick is that polyethylene and GRP are transparent to it — so the sensor can sit on the outside of the tank and read through the wall. That’s Gobius C: stepless 0–100 % from a sensor taped to the tank top. Limit: radar does not pass metal.

6. Vibration — the only one that does metal from outside

Tap a tank wall below the liquid line and it sounds dead; above, it rings. Instrument that effect — a controlled excitation and an accelerometer — and you can detect liquid presence through any wall: steel, stainless, aluminium, plastic, GRP. Each sensor reads one level, so you place them where decisions happen (25/50/75/100 %, or a single “almost full”). That’s the patented method inside Gobius Pro and Original — and the only fully external option for metal tanks. Limit: no stepless measurement.

Summary

All six, side by side

FeatureHole neededFouls in wasteMetal tanksResolution
Float senders YesSticks Yes (with hole)10–25 % steps
CapacitiveProbe: yes · strip: noCoats✕ No±5–10 %
Pressure YesClogs Yes (with a hole)Good, calm tanks
Ultrasonic yesVapour issues yes, (with a hole)±1–2 cm
Radar (Gobius C) Yes (polythelene/GRP)OutsideAdapter needed2 mm
Gobius Pro and OriginalNeverOutsideThrough the tank wallExact levels

Choosing rule: polyethelene/GRP tank → radar for correct volume in liters/gallon and %. Metal tank, or you want outputs/alarms → vibration. Both stay outside the tank.

Questions

Choosing a sensor — frequently asked

What is the most accurate tank level sensor?

For small tanks (boats, RVs): radar, 2 mm resolution. Pressure sensors can match it in tall, stationary tanks but need to contact the liquid. Floats and capacitive senders are the least accurate over time because fouling degrades them.

What is the best sensor for a waste or black water tank?

An external one — anything inside a holding tank will foul. Radar through the wall (plastic tanks) or vibration on the wall (any material) measure without touching the contents. See black water sensors.

Can any sensor measure through a metal tank wall?

Only vibration-based measurement. Radar and ultrasound are blocked by conductive walls, capacitive strips are shorted by them, and everything else needs a hole. That is the niche that Gobius Pro and Original were patented for.

Do I always need 0–100 % readout?

No — for many holding tanks, one well-placed level point (“75 % — plan a pump-out”) is more actionable than a percentage. Stepless readout shines on fresh water and fuel, where you ration against a plan.

Ready to see the correct volume in your tank?

Order directly from us or find your nearest dealer. Installation takes about 15 minutes.