Superyachts · refit & new build

A dozen tanks. One place to read them.

Fresh water, grey, black and fuel — every tank on the vessel in one overview the engineer and the crew can trust, so nobody is sent below with a sounding tape.

  • Nothing inside the tank
  • Fitted afloat
  • On the displays you already have
Superyacht at anchor in clear blue water
0senders inside the tank
2 mmGobius C, resolution
0–100 %Gobius C, continuous
Afloatno haul-out, no draining

One overview

The whole tank farm, read from one place

Fresh water forward and aft, grey and black holding, day tanks, bunkers, transfer tanks. Each one gets its own sensor, named as the crew know it, and they are read together.

Numbers worth trusting

Gobius C measures volume with micro radar from the top of the tank: stepless 0–100% resolution, 2 mm, for tanks 200–4500 mm deep.

Nothing inside the tank

No float, no probe, no rod standing in black water or diesel. There is no in-tank sender to foul, seize or pull for service somewhere nobody wants to reach.

Warned in good time

Black water approaching full before a guest week, fuel below transfer minimum, fresh water low before a long leg. Set the point per tank and it flags itself.

Refit

Fitted alongside, not on the hard

The sensors mount on the outside of the tank, so the usual reasons a gauging job waits for a yard period fall away.

  1. 01

    Survey the tanks

    Material, wall thickness, depth and the access above each tank. Nothing is opened or emptied to do this.

  2. 02

    Mount from outside

    Gobius C on the tank top, Gobius Pro on the side wall. No tank entry and no gas-freeing — the tanks stay in service throughout.

  3. 03

    Set up and hand over

    Each tank named as the crew know it, alarm points agreed. Around 15 minutes per sensor once the cable run is prepared.

What it avoids

The parts nobody wants

Haul-outNot needed. The work is inside the vessel, on the outside of the tank
Draining tanksNot needed. Tanks stay full, sealed and in service
Tank entryNot needed. Nobody goes inside the tank, so there is no confined-space work
In-tank senderNone, so nothing to foul or service later
Polythelene, fibreglassGobius C is fully external — nothing drilled at all

Drawings and manuals for the yard: downloads.

Readouts

It appears where the crew already looks

Tank volumes and levels don't need to live in their own app.

The Gobius app

Volumes and levels over Bluetooth, so the chief stew can check the black tank without walking to a panel.

NMEA 2000 and Analog version

Gobius C goes onto the boat network for plotters and monitoring panels, and to a Victron Cerbo GX/Ekrano GX and Roam Hub from Roam Devices, wireless.

The existing panel

Analog outputs (0-190/240-33 Ohm, 4-20 mA, and 0-5 Volt) drive gauges are already fitted, so nothing on the bridge needs to be replaced.

Which sensor

Gobius C or Gobius Pro

Gobius C reads down from the tank top and displays the liter/gallon and percentage. It is fully external on plastic and fiberglass tanks; on a metal tank, it needs a small hole fitted in the top, because radar will not pass through steel or aluminum.

Gobius Pro is glued to the outside of the tank wall and reads from the side through any material, metal included, with nothing drilled. Each Pro sensor gives one fixed alarm point rather than a percentage, and can switch a lamp, buzzer or pump. Many vessels use both. Compare them side by side.

  • Captains
  • Chief engineers
  • Refit yards
  • Specifiers

Send us the tank schedule

Tank count and service, material and wall thickness, depth, and what the bridge and engine room already display. We will come back with a layout — and say plainly if a tank is a poor fit.

Questions

What captains and engineers ask

Our tanks are in steel. What then?

Radar will not pass through metal, so Gobius C needs a small port in the tank top. Where opening the tank is not acceptable, Gobius Pro bonds to the side wall — stainless steel and steel <3 mm, aluminium <5 mm, polythelene <12 mm — and gives also alarm points.

Can it be fitted between charters?

Yes. No hull work and no tank entry, and the tanks stay in service, so the job runs afloat alongside other trades.

What maintenance does the crew have?

None in normal service. Nothing moves and nothing sits in the liquid. IP 66, CE and EMC certified, designed in Sweden.

Bring every tank into one picture

Send the tank list for the vessel — service, material and capacity — and we will propose a layout.