Support · Installation
Installation guides & downloads
Reckon on roughly fifteen minutes per sensor. Gobius C goes on top of the tank; Gobius Pro and Original go on the outside of the wall. Follow the steps, then take the documents you need from the downloads further down.
Gobius C — on top of the tank
- 01
Position
A flat, horizontal spot on the tank top with a clear “view” straight down to the bottom.
- 02
Clean & mount
Wipe with the supplied 3M pad. Press the sensor onto its pre-applied 3M tape for 10 seconds.
- 03
Wire 12–24 V
Two wires to a 12–24 V DC supply, through a fast-acting (F) 500 mA, 250 V fuse. The NMEA 2000 variant takes power from the network instead.
- 04
Installation in the app
The Gobius app walks you through it. Name the tank, and you'll read a stepless 0–100%.
Plastic, polyethylene and fibreglass need nothing drilled. A metal tank needs a small hole in the top for the 1¼"/SAE-5 adapter — or put Gobius Pro or Original on the side wall instead.
Gobius Pro — on the tank wall
- 01
Choose level points
Each sensor reports one fixed level, wet or dry — one where you want the warning, or several up the wall.
- 02
Clean & glue
Clean each spot, apply the supplied adhesive (3M), press the sensor firmly flat against the outside of the wall.
- 03
Wire or relay
12–24 V supply through a fast-acting (F) 500 mA, 250 V fuse; add a lamp or buzzer that should react to an alarm point. For a pump, you need a relay.
- 04
Installation in the app
Teach each sensor “empty” or “full” against a known level. The app then shows them all together as one tank.
Reads through any material, metal included, with nothing drilled — the wall-thickness limit for each material is on limits & specifications.
Good to know
Rules of thumb for C sensors
| Room above the tank | >79 mm on a plastic tank; >100 mm on a metal tank, where the adapter is fitted |
|---|---|
| Fitting temperature | At least 20 °C — the adhesive needs warmth to key properly |
| Gobius C calibration | >150 mm air gap sensor → surface |
| Gobius C measuring | 200–4500 mm depth, 2 mm resolution, 12–24 V DC, IP 66 |
| “Full” definition | 100 % is read 40 mm below the tank top — overflow margin built in |
| Cable runs | Standard marine practice — fused, chafe-protected |
| Fuse | Fast acting (F), 500 mA, 250 V, supplied by you |
Protect it with a fuse
To prevent damage to the sensor and potential hazards to personnel, the sensor and all connected external equipment (gauges, lamps, etc.) must be protected by a user-supplied fuse compliant with the following specification:
• Type: Fast acting (F)
• Current rating: 500 mA
• Voltage rating: 250 V
Edge clearances, baffles and how much bare wall each sensor needs are all set out under limits & specifications.
The app
Set-up happens on your phone
The Gobius app is free on iOS and Android, in ten languages. It talks to the sensor over Bluetooth — no hub in between, and no account to create.
App for iOS
From the App Store.
App for Android
From Google Play.
The app mirrors these steps as you go, so most installs never open the PDF. Quick Guide in English.
Downloads
Manuals, quick starts and datasheets
Every document for every product, in one place — the deep technical detail we keep off the product pages. Each link opens a PDF.
| Manual | Gobius C manual — mounting, calibration, alarm levels, fault finding |
|---|---|
| Quick Guide | Gobius C quick start — the card from the box |
| Datasheet | Gobius C datasheet — dimensions, materials, supply, range, interfaces |
| Metal tanks | Port & adapter fitting sheet — the opening a metal tank needs |
| Manual | Gobius Pro manual — the full procedure and fault finding |
|---|---|
| Quick Quide | Gobius Pro quick start — on one page |
| Datasheet | Gobius Pro datasheet — wall-thickness limits per material, power, outputs |
| Relays | Outputs & relay wiring — wiring an alarm point to a relay |
| Manual | Tank Calculator manual — preparing the tank, step size, saving the profile |
|---|---|
| Quick start | Tank Calculator quick start — on one page |
| What it is | A separate, standalone app. It needs a Gobius C and does not work with Gobius Pro. |
| CE declarations | Declaration of conformity for Gobius C, Gobius Pro and accessories |
|---|---|
| Materials | Materials statement — what touches the liquid |
| Warranty | Full warranty terms; register yours on the warranty page |
Documents for older Gobius generations are not all listed here — tell us the product and we will send the right PDF.
If it does not behave
Where to go next
A reading that jumps, drifts or will not calibrate is nearly always placement. Work through troubleshooting, then check what the sensors genuinely cannot do under limits & specifications.
Still stuck, or after a document that is not listed? Contact us. General questions are answered on the FAQ.
15 minutes from now, you get correct volume in liter/gallon and %
Everything you need is in the box.