Support · limits & specifications
What each sensor needs from your tank
Depths, clearances, wall thicknesses and materials — the numbers that decide whether a tank is a yes, a no, or a job for the other sensor. For where on the tank the sensor actually goes, see Measurement rules.
Gobius C · from the top
What radar reads through
Micro radar sits on the tank top and measures straight down to the surface: 2 mm resolution, stepless 0–100 %, nothing inside the tank.
Where it sits is its own subject. The sensor needs a horizontal patch on the tank top, a clear run straight down, and a flat surface to reflect from — which on a molded tank is not always obvious. Measurement rules work through seven tank shapes in drawings.
Metal needs a hole. Radar goes straight through polyethylene <12 mm and fiberglass <8 mm, nothing drilled. Metal — and fiberglass >8 mm — needs a small hole and an adapter at the top; if the tank must stay sealed, use Gobius Pro or Original.
| Tank depth | 200–4500 mm |
|---|---|
| Clearance when full | 40 mm minimum, sensor to liquid surface |
| Resolution | 2 mm |
| Reading | Stepless 0–100 % |
| Power & protection | 12–24 V DC · IP 66 |
| Fuse | Required, user-supplied: fast acting (F), 500 mA, 250 V |
Any fluid reads the same — water, diesel, petrol, oil, grey and black water. The wall is the limitation. See Gobius C.
Gobius Pro · from the side
One sensor, one height, one answer
Gobius Pro glues to the outside of a side wall and reads through it — any material, metal included, nothing drilled, nothing inside the tank.
Pro gives a level, not a percentage. Each sensor answers one question at its own height: has the liquid reached this point? That is an alarm point, enough to switch a pump on its own. Four sensors give a 25/50/75/100 staircase, and nothing in between. For a figure that falls liter by liter, you want Gobius C.
The wall decides the spot. The height you glue it at is the level it reports, and the adhesive is permanent — so it is worth a minute on the sketches below.
| Stainless steel | Tank wall <3 mm |
|---|---|
| Steel | Tank wall <3 mm |
| Aluminium | Tank wall <5 mm |
| Plastic / polyethylene | Tank wall <12 mm |
| Fibreglass | Tank wall <8 mm |
| Reading | One fixed level per sensor |
| Fuse | Required, user-supplied: fast acting (F), 500 mA, 250 V |
Thick bitumen, paint, or tiling behaves like an extra wall — delete it before you start installation. See Gobius Pro.
Where on the wall each sensor goes — the five spots that fail and what a good one looks like — is drawn out on Measurement rules.
The short answer
If your tank is like this, expect this
Find the row that matches your tank. Where both work, pick the answer you want.
| Your tank | Gobius C — from the top | Gobius Pro — from the side |
|---|---|---|
| Polyethelene, plastic | Ideal up to a 12 mm wall — nothing opened, continuous per cent | Works up to a 12 mm wall, if alarm points are all you need |
| Fibreglass | Fully external up to 8 mm; a thicker wall needs an adapter and a hole in the top | Fine up to an 8 mm wall |
| Stainless steel or aluminium | Radar cannot pass metal — needs a port | Max 3 mm stainless steel/steel, 5 mm aluminium |
| Under 200 mm or over 4.5 m deep | Outside the measuring range | Fine — it only reads its own level |
| Top boxed in, only the side reachable | Nowhere to mount | The reason Gobius Pro exists |
| Baffles, sumps, sloping floor | Sit over the deepest clear part, with a clear view down | Mount clear of baffle attachment points |
| Insulated, clad or double-walled | Needs bare tank wall exposed | Needs bare tank wall exposed |
| Soft or flexing walls | Usually no problem, provided the upper part of the tank retains its horizontal shape. | The wall must stay where you put it |
| Old tank, heavy crust inside | Unaffected — it reads the surface from above | A crust at sensor height reads like liquid |
Irregular tank? The Tank Calculator turns a Gobius C depth into true litres.
Odd tank? Send us a photo.
Tell us the material, the wall thickness, roughly the shape and where you can reach it. We will say which sensor fits and where to put it — and honestly if neither does. Designed in Sweden; Support responds on weekdays, 9–17 CET.