Depths, clearances, wall thicknesses and materials — the numbers that decide whether a tank is a yes, a no, or a job for the other sensor. For where on the tank the sensor actually goes, see Measurement rules.

Gobius C · from the top

What radar reads through

Micro radar sits on the tank top and measures straight down to the surface: 2 mm resolution, stepless 0–100 %, nothing inside the tank.

Where it sits is its own subject. The sensor needs a horizontal patch on the tank top, a clear run straight down, and a flat surface to reflect from — which on a molded tank is not always obvious. Measurement rules work through seven tank shapes in drawings.

Metal needs a hole. Radar goes straight through polyethylene <12 mm and fiberglass <8 mm, nothing drilled. Metal — and fiberglass >8 mm — needs a small hole and an adapter at the top; if the tank must stay sealed, use Gobius Pro or Original.


Tank depth200–4500 mm
Clearance when full40 mm minimum, sensor to liquid surface
Resolution2 mm
ReadingStepless 0–100 %
Power & protection12–24 V DC · IP 66
FuseRequired, user-supplied: fast acting (F), 500 mA, 250 V

Any fluid reads the same — water, diesel, petrol, oil, grey and black water. The wall is the limitation. See Gobius C.

Gobius Pro · from the side

One sensor, one height, one answer

Gobius Pro glues to the outside of a side wall and reads through it — any material, metal included, nothing drilled, nothing inside the tank.

Pro gives a level, not a percentage. Each sensor answers one question at its own height: has the liquid reached this point? That is an alarm point, enough to switch a pump on its own. Four sensors give a 25/50/75/100 staircase, and nothing in between. For a figure that falls liter by liter, you want Gobius C.

The wall decides the spot. The height you glue it at is the level it reports, and the adhesive is permanent — so it is worth a minute on the sketches below.

Stainless steelTank wall <3 mm
SteelTank wall <3 mm
AluminiumTank wall <5 mm
Plastic / polyethyleneTank wall <12 mm
FibreglassTank wall <8 mm
ReadingOne fixed level per sensor
FuseRequired, user-supplied: fast acting (F), 500 mA, 250 V

Thick bitumen, paint, or tiling behaves like an extra wall — delete it before you start installation. See Gobius Pro.

Where on the wall each sensor goes — the five spots that fail and what a good one looks like — is drawn out on Measurement rules.

The short answer

If your tank is like this, expect this

Find the row that matches your tank. Where both work, pick the answer you want.

Your tankGobius C — from the topGobius Pro — from the side
Polyethelene, plasticIdeal up to a 12 mm wall — nothing opened, continuous per centWorks up to a 12 mm wall, if alarm points are all you need
FibreglassFully external up to 8 mm; a thicker wall needs an adapter and a hole in the topFine up to an 8 mm wall
Stainless steel or aluminiumRadar cannot pass metal — needs a portMax 3 mm stainless steel/steel, 5 mm aluminium
Under 200 mm or over 4.5 m deepOutside the measuring rangeFine — it only reads its own level
Top boxed in, only the side reachableNowhere to mountThe reason Gobius Pro exists
Baffles, sumps, sloping floorSit over the deepest clear part, with a clear view downMount clear of baffle attachment points
Insulated, clad or double-walledNeeds bare tank wall exposedNeeds bare tank wall exposed
Soft or flexing wallsUsually no problem, provided the upper part of the tank retains its horizontal shape.The wall must stay where you put it
Old tank, heavy crust insideUnaffected — it reads the surface from aboveA crust at sensor height reads like liquid

Irregular tank? The Tank Calculator turns a Gobius C depth into true litres.

Odd tank? Send us a photo.

Tell us the material, the wall thickness, roughly the shape and where you can reach it. We will say which sensor fits and where to put it — and honestly if neither does. Designed in Sweden; Support responds on weekdays, 9–17 CET.